  1 z ethernet gateway for red lion panel meters with rlc serial protocol z programmable via crimson ? software z usb programming port z extensive ethernet driver list allows easy data mapping to plcs, pcs, and scada systems z 10 base-t/100 base-tx ethernet general description the icm8 is designed to act as an ethernet gateway offering multiple protocol conversion for red lion panel meters. with two serial ports (one rs232 and one rs485) and a 10 base-t/100 ethernet port, the unit performs protocol conversion, allowing red lion panel meters to communicate seamlessly to the ethernet network. programming the unit can be accomplished via the rs232 or the usb port using crimson ? software. it is important to note that this device is designed to function with red lion panel meters and will not offer protocol conversion if a red lion product is not connected to at least one of the serial ports. the icm8s din rail mounting saves time and panel space and snaps easily onto standard top hat (t) profile din rail. software the icm8 is programmed with windows ? compatible crimson software. the software is an easy to use graphical interface that can be downloaded free of charge from www.redlion.net. safety summary all safety related regulations, local codes and instructions that appear in the manual or on equipment must be observed to ensure personal safety and to prevent damage to either the instrument or equipment connected to it. if equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. ordering information model no. description part number icm8 communication gateway ICM80000 psdr din rail power supply psdrxxxx sfcrd2 crimson 2.0 programming software 2 sfcrd2xx cbl rs-232 programming cable cblprog0 usb cable cblusb00 communications cables 1 cblxxxxx dr din rail mountable adapter products 3 drxxxxxx 1 contact your red lion distributor or visit our website for complete selection. 2 free at www.redlion.net 3 red lion offers rj modular jack adapters. refer to the dr literature for complete details. caution: risk of danger. read complete instructions prior to installation and operation of the unit. model icm8 C ethernet gateway for red lion panel meters with rlc serial protocol bulletin no. icm8-d drawing no. lp0642 released 01/15 tel +1 (717) 767-6511 fax +1 (717) 764-0839 www.redlion.net 4.15 (105.4) 5.30 (134.7) 1.75 (44.5) dimensions i n inches ( mm )
2 specifications 1. power : 24 vdc 10% 200 ma max. must use a class 2 circuit according to national electrical code (nec), nfpa-70 or canadian electrical code (cec), part i, c22.1 or a limited power supply (lps) according to iec 60950-1 or limited-energy circuit according to iec 61010-1. 2. communications : usb/pg port : adheres to usb specification 1.1. device only using type b connection. serial ports : format and baud rates for each port are individually software programmable up to 115,200 baud. rs232/pg port : rs232 port via rj12 comms ports : rs485 port via rj11 ethernet port : 10 base-t / 100 base-tx 3. leds : sts C status led indicates condition of icm8. tx/rx C transmit/receive leds show serial activity. ethernet C link and activity leds. 4. memory : on-board user memory: 4 mbytes of non-volatile flash memory. on-board sdram: 2 mbytes 5. certifications and compliances : ce approved en 61326-1 immunity to industrial locations emission cispr 11 class a safety requirements for electrical equipment for measurement, control, and laboratory use: en 61010-1: general requirements ip20 enclosure rating 6. environmental conditions : operating temperature range: 0 to 50c storage temperature range: -30 to +70c operating and storage humidity: 80% max relative humidity, non-condensing, from 0 to 50c vibration to iec 68-2-6: operational 5 to 150 hz, 2 g. shock to iec 68-2-27: operational 25 g. altitude: up to 2000 meters 7. construction : case body is black high impact plastic and stainless steel. installation category i, pollution degree 2. 8. power connection : removable wire clamp screw terminal block. wire gage capacity: 24 awg to 12 awg torque: 4.45 to 5.34 in/lb (0.5 to 0.6 n-m) 9. mounting : snaps onto standard din style top hat (t) profile mounting rails according to en50022 -35 x 7.5 and -35 x 15. 10. weight : 12.3 oz (348g) hardware installation fie - ach icm8 t din ri power supply requirements it is very important that the power supply is mounted correctly if the unit is to operate reliably. please take care to observe the following points: C the power supply must be mounted close to the unit, with usually not more than 6 feet (1.8 m) of cable between the supply and the icm8. ideally, the shortest length possible should be used. C the wire used to connect the icm8s power supply should be at least 22-gage wire. if a longer cable run is used, a heavier gage wire should be used. the routing of the cable should be kept away from large contactors, inverters, and other devices which may generate significant electrical noise. C a power supply with a class 2 or selv rating is to be used. a class 2 or selv power supply provides isolation to accessible circuits from hazardous voltage levels generated by a mains power supply due to single faults. selv is an acronym for safety extra-low voltage. safety extra- low voltage circuits shall exhibit voltages safe to touch both under normal operating conditions and after a single fault, such as a breakdown of a layer of basic insulation or after the failure of a single component has occurred. 2 1 24vdc 10% comms port rs232/pg port rts (pin 6) cts (pin 1) usb/pg rs232 comm tx comm rx power connector n/c 3 2 common 1 ethernet rs485 rs232/pg usb/pg sts ethernet (nic) orange green/ led led amber port rs485 nc nc (pin 1) nc (pin 6) a (+) comm b (-) icm8 port pin outs
3 wiring power connection common +24 vdc 3 12 --- 23 1 +24 n/c comm emc installation guidelines although red lion controls products are designed with a high degree of immunity to electromagnetic interference (emi), proper installation and wiring methods must be followed to ensure compatibility in each application. the type of the electrical noise, source or coupling method into a unit may be different for various installations. cable length, routing, and shield termination are very important and can mean the difference between a successful or troublesome installation. listed are some emi guidelines for a successful installation in an industrial environment. 1. a unit should be mounted in a metal enclosure, which is properly connected to protective earth. 2. use shielded cables for all signal and control inputs. the shield connection should be made as short as possible. the connection point for the shield depends somewhat upon the application. listed below are the recommended methods of connecting the shield, in order of their effectiveness. a. connect the shield to earth ground (protective earth) at one end where the unit is mounted. b. connect the shield to earth ground at both ends of the cable, usually when the noise source frequency is over 1 mhz. 3. never run signal or control cables in the same conduit or raceway with ac power lines, conductors, feeding motors, solenoids, scr controls, and heaters, etc. the cables should be run through metal conduit that is properly grounded. this is especially useful in applications where cable runs are long and portable two-way radios are used in close proximity or if the installation is near a commercial radio transmitter. also, signal or control cables within an enclosure should be routed as far away as possible from contactors, control relays, transformers, and other noisy components. 4. long cable runs are more susceptible to emi pickup than short cable runs. 5. in extremely high emi environments, the use of external emi suppression devices such as ferrite suppression cores for signal and control cables is effective. the following emi suppression devices (or equivalent) are recommended: fair-rite part number 0443167251 (rlc part number fcor0000) line filters for input power cables: schaffner # fn2010-1/07 (red lion controls # lfil0000) 6. to protect relay contacts that control inductive loads and to minimize radiated and conducted noise (emi), some type of contact protection network is normally installed across the load, the contacts or both. the most effective location is across the load. a. using a snubber, which is a resistor-capacitor (rc) network or metal oxide varistor (mov) across an ac inductive load is very effective at reducing emi and increasing relay contact life. b. if a dc inductive load (such as a dc relay coil) is controlled by a transistor switch, care must be taken not to exceed the breakdown voltage of the transistor when the load is switched. one of the most effective ways is to place a diode across the inductive load. most rlc products with solid state outputs have internal zener diode protection. however external diode protection at the load is always a good design practice to limit emi. although the use of a snubber or varistor could be used. rlc part numbers: snubber: snub0000 varistor: ils11500 or ils23000 7. care should be taken when connecting input and output devices to the instrument. when a separate input and output common is provided, they should not be mixed. therefore a sensor common should not be connected to an output common. this would cause emi on the sensitive input common, which could affect the instruments operation. visit rlcs web site at http://www.redlion.net/support/installationconsiderations. html for more information on emi guidelines, safety and ce issues as they relate to red lion controls products. programming ports rs232 rt s comm tx comm cts rx cblprog0 or cblusb0 0 rs232/pg usb/pg troubleshooting 1. this module is designed to operate with red lion panel meters only. please make sure a red lion product is connected to either one of the two serial ports for the gateway to be active. 2. the ethernet port is equipped with data leds. if they are blinking, the converter is active and the data is available at the port. please verify the receiving equipment is properly programmed. 3. if for any reason you have trouble operating, connecting, or simply have questions concerning your new icm8, contact red lions technical support. for contact information, refer to the back page of this bulletin for phone and fax numbers. email: techsupport@redlion.net web site: http://www.redlion.net
4 4 rs485 nc (pin 1) nc (pin 6) a (+) b (-) comm nc rst cblxxxxx* dsp t t o n x m m i a par f f1 2 v p s 1p s 2 p s3 p s 4 8.8.8.8.8 red lion panel meter (w/rlc serial protocol) * use appropriate communications cable. see ordering information for descriptions of the available cables. rs485 communication ports tx rs232 rt s comm comm cts rx cblprog0 or cblxxxxx* s  dsp n i m o t t a m x pa r f 1 ss 1 p 2 p rst 2 f v 3 p s 4 p red lion panel meter (w/rlc serial protocol) rs232/pg standard ethernet cable green/orange led amber led port 3 - ethernet connection
5 configuring the icm8 the icm8 is configured using crimson software. crimson is available as a free download from red lions website, or it can be ordered on cd. updates to crimson for new features and drivers are posted on the website as they become available. crimson software can configure the icm8 through the rs232/pg port or usb/pg port. the usb/pg port is connected using a standard usb cable with a type b connector. the driver needed to use the usb port will be installed with crimson. the rs232/pg port uses a programming cable made by red lion to connect to the db9 com port of your computer. if making your own cable, refer to the icm8 port pin outs for wiring information. ethernet communications ethernet communications can be established at either 10 base-t or 100 base-tx. the crimson manual contains additional information on ethernet communications. rs232 ports the icm8 has one rs232 port. the port can be used for programming or communications. rs485 port the icm8 has one rs485 port. note: all red lion devices connect a to a and b to b. * rs485 common connection is optional. communicating with the icm8 comm receiving device rxd txd 5 dte 2 3 db9 rx comm tx comm cts rt s icm8 rs232/pg por t rs232 red lion panel meter (w/rlc serial protocol) receiving device b (-) a (+) comm.* red lion panel meter (w/rlc serial protocol) icm8 comms por t nc nc a (+) nc comm b (-) rs485 leds sts C status led the green status led provides information regarding the state of the icm8. this includes indication of the various stages of the start-up routine (power-up), and any errors that may occur. startup routing user communication ports - tx/rx leds ethernet leds indication rail flashing stea icm8 is oerating roerl icm8 is currentl running the oot loaer an/or eing flash ugrae crison led indication green transitting red receiing led indication yellow soli link estalishe yellow flashing netork actiit green 1 base-t counications amber 1 base-t counications
6 this page intentionally left blank
7 this page intentionally left blank
limited warranty the company warrants the products it manufactures against defects in materials and workmanship for a period limited to two years from the date of shipment, provided the products have been stored, handled, installed, and used under proper conditions. the companys liability under this limited warranty shall extend only to the repair or replacement of a defective product, at the companys option. the company disclaims all liability for any affirmation, promise or representation with respect to the products. the customer agrees to hold red lion controls harmless from, defend, and indemnify rlc against damages, claims, and expenses arising out of subsequent sales of rlc products or products containing components manufactured by rlc and based upon personal injuries, deaths, property damage, lost profits, and other matters which buyer, its employees, or sub-contractors are or may be to any extent liable, including without limitation penalties imposed by the consumer product safety act (p.l. 92-573) and liability imposed upon any person pursuant to the magnuson-moss warranty act (p.l. 93-637), as now in effect or as amended hereafter. no warranties expressed or implied are created with respect to the companys products except those expressly contained herein. the customer acknowledges the disclaimers and limitations contained herein and relies on no other warranties or affirmations. red lion controls headquarters 20 willow springs circle york pa 17406 tel +1 (717) 767-6511 fax +1 (717) 764-0839 red lion controls china unit 302, xinan plaza building 13, no.99 tianzhou road shanghai, p.r. china 200223 tel +86 21 6113 3688 fax +86 21 6113 3683 red lion controls europe softwareweg 9 nl - 3821 bn amersfoort tel +31 (0) 334 723 225 fax +31 (0) 334 893 793 red lion controls india 201-b, 2nd floor, park centra opp 32 mile stone, sector-30 gurgaon-122002 haryana, india tel +91 984 487 0503


▲Up To Search▲   

 
Price & Availability of ICM80000

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X